TRA-CON offers proven adhesive systems for biomedical
applications ranging from the assembly and repair of catheters,
guide wires, probes, as well as sophisticated medical imaging and
monitoring equipment. These products include USP Class VI approved
materials used for needle bonding, hearing aids, and dental instruments,
along with materials which pass ISO (10993-5) elution cytotoxicity
study.
Download this Biomedical Application Guide Brochure with Technical Data
Sheets.
|
|
Product
|
Description
|
Viscosity
|
Pot Life
|
Hardness
(Shore D)
|
Cure Schedule
|
| TRA-BOND
FDA-2 |
Med. viscosity, USP Class VI
|
14,000 cps
|
45 min
|
80
|
24 hrs @ 25°C
1 hr @ 65°C
|
| TRA-BOND
FDA-2T |
High strength, USP Class VI
|
Thixotropic
|
45 min
|
80
|
24 hrs @ 25°C
1 hr @ 65°C
|
| TRA-BOND
FDA-8 |
Flexible, low viscosity
|
1,500 cps
|
45 min
|
65
|
24 hrs @ 25°C
4 hrs @ 65°C
|
| TRA-BOND
FDA-8T |
Thixotropic, flexible
|
42,000 cps
|
45 min
|
60
|
24 hrs @ 25°C
2 hrs @ 65°C
|
| TRA-BOND
FDA 12 |
Medium viscosity
Light yellow
|
9,000 cps
|
50 min
|
82
|
72 hrs @ 25°C
1-2 hrs @ 65°C
|
| TRA-BOND
FDA-15 |
Rigid, clear
|
4,500 cps
|
25 min
|
89
|
24 hrs @ 25°C
4 hrs @ 65°C
|
| TRA-BOND
FDA-16 |
Low viscosity, USP Class VI
|
4,700 cps
|
25 min
|
75
|
72 hrs @ 25°C
4 hrs @ 65°C
|
| TRA-BOND
FDA-22 |
High viscosity
|
28,000 cps
|
3 hrs
|
78
|
24 hrs @ 25°C
1 hr @ 65°C
|
| TRA-BOND
FDA-23 |
Higher viscosity
|
65,000 cps
|
3 hrs
|
78
|
24 hrs @ 25°C
1 hr @ 65°C
|
| TRA-BOND
2105 |
Medium viscosity exothermic
|
6,000 cps
|
20 min
|
84
|
1-4 hrs @ 65°C
|
| TRA-DUCT
2902 |
Electrically Conductive
|
Smooth paste
|
60 min
|
80
|
24 hrs @ 25°C
1 hr @ 65°C
|
| TRA-CAST
3103 |
Casting material
|
4,000 cps
|
30 min
|
85
|
24 hrs @ 25°C
4 hrs @ 65°C
|
| TRA-BOND
716K01 |
Radio opaque
|
13,000 cps
|
3 hrs
|
91
|
24 hrs @ 25°C
1 hr @ 65°C
|
| TRA-BOND
F114 |
Very low viscosity, clear
|
625 cps
|
40 min
|
83
|
24 hrs @ 25°C
4 hrs @ 65°C
|
 |
 |
|
Application
|
FDA2
|
FDA2T
|
FDA8
|
FDA8T
|
FDA12
|
FDA15
|
FDA16
|
FDA22
|
FDA23
|
2105
|
2902
|
3103
|
716K01
|
F114
|
|
Medical
Device Assembly and Food Preparation
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Laminating
and Repair of Food/Medical Equipment
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Medical
Adhesive for Fiber Optics
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Biomedical
Assembly
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Coating,
Sealing
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Electrically
Conductive
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Thermally
Conductive
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
"Cold’
Solder, EMI/RFI/ESD
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Radio
Opaque
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Casting,
Potting
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
USP
Class VI Approved
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Cytotoxicity
ISO Elution Passed
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
NASA
Outgassing Passed
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Note: All values shown are TYPICAL. Because the
conditions of use are beyond our control and can significantly affect
the results obtained from the materials listed above, all recommendations